₹ 8000 / Piece Get Latest Price
| Fan Size | 400 mm |
| Flow Rate | 5000 cm3/h |
| Air Flow | 5000 m³/hr |
| Static Pressure | 400 Pa |
| Power | AC |
| Voltage | 440 |
| Capacity | 6000 CFM |
| Fan Speed | 1440 |
| Type | Duct Mounted Fan, Wall Mounted Fan, V Belt Driven Units |
| Blade Material | Stainless Steel, Aluminium Casting |
| Application | Ventilation, Tunnel, Industrial, Exhaust |
| Brand | COOLVENT TECHNOLOGY |
| Size | 300 MM TO 1600MM |
| Usage/Application | VENTILATION |
Minimum order quantity: 1 Piece
A Tubeaxial Flow Fan is a high-efficiency axial-type industrial fan designed to move large volumes of air through a cylindrical housing. The fan consists of an axial impeller mounted inside a tube-shaped casing, allowing air to flow parallel to the fan shaft. Tubeaxial fans deliver strong airflow with moderate static pressure, making them ideal for ventilation, exhaust, cooling, and air-circulation in industrial and commercial applications.
These fans are compact, lightweight, and efficient, offering reliable performance in environments where space is limited but powerful airflow is required.
⭐ Key Features ✔ Tubular Housing DesignThe aerodynamic cylindrical casing ensures smooth airflow with minimal resistance and noise.
✔ High-Volume Air MovementSuitable for moving large airflow at medium pressure, ideal for ventilation and general exhaust.
✔ Axial Impeller ConstructionHeavy-duty blades (aluminum/plastic/FRP/steel) provide efficient air delivery and balanced, vibration-free performance.
✔ Direct or Belt Drive OptionsDirect-drive for compact, low-maintenance installations
Belt-drive for adjustable speed and higher pressure needs
Can be installed inline with ductwork for supply or exhaust air, or mounted on walls for general room ventilation.
🚀 Where Tubeaxial Fans Are UsedIndustrial ventilation & exhaust
Warehouses & factories
Air Handling Units (AHUs)
Paint booths
Workshops & manufacturing plants
Commercial kitchens
Tunnels & underground ventilation
Greenhouses, poultry & livestock sheds
Cooling for generators, machinery & heat-producing equipment
High airflow capacity
Direct, straight-line air movement
Low noise compared to conventional axial fans
Energy-efficient design
Suitable for long duct runs with moderate static pressure
Easy installation and maintenance
₹ 20000 / Piece Get Latest Price
| Airflow | 20000 CFM |
| Application | Industrial |
| Insulation type | PUF |
| Panel thickness | 25 mm |
| Static pressure | 50 mmWG |
| Fan type | Backward curve |
| Filter stage | Pre plus HEPA, Pre plus fine, Three stage, With carbon, Pre filter |
| Cooling coil rows | 6 row |
| Mounting | Floor mounted |
| Brand | In house |
Minimum order quantity: 1 Piece
A dual-skin AHU uses two layers (skins) for the casing: an inner sheet and an outer sheet, with a layer of insulation between them (commonly PUF / PIR / mineral wool or similar).
Panel thickness is often 25 mm, 50 mm, etc., depending on the insulation requirement.
The structure is typically built on a rigid frame (e.g. extruded aluminium or galvanized steel base frame) for strength and durability.
Essentially — instead of a simple single-sheet metal casing, dual-skin AHUs sandwich insulation between two skins to provide much better thermal, acoustic, and structural performance.
🎯 What Makes Double-Skin AHUs a “Disruption” (Advantages over conventional AHUs)Using a dual-skin AHU gives several important benefits over traditional / single-skin AHUs:
Thermal Insulation & Energy Efficiency: The insulated double-wall prevents unwanted heat gain/loss, reduces thermal bridging, and helps maintain stable supply-air temperature and humidity — reducing the load on chillers or heaters.
Noise Reduction & Vibration Dampening: The insulation between skins acts as a sound-absorbing barrier. This reduces fan noise, airflow noise, and mechanical vibration noise — important for comfort in offices, hospitals, hotels, etc.
Reduced Air Leakage & Better Sealing: The double-skin modular design with tight panel joints reduces leakage; ensuring designed air-flows, better pressure control, and improved energy efficiency.
Structural Strength & Durability: The dual panels and insulated core give more rigidity and robustness — making the unit suitable for rooftop installations, large-volume HVAC systems, or industrial conditions.
Better Air Quality & Hygiene (for sensitive applications): Because of better sealing and design, double-skin AHUs can incorporate advanced filtration (pre-filters, fine filters, HEPA, etc.), coils (chilled water / DX), humidification/dehumidification, and other HVAC components — making them apt for hospitals, pharma, labs, cleanrooms, etc.
Flexibility & Customization: These units are often modular, so they can be custom-designed for airflow capacity (CFM/m³/h), static pressure, fan type (forward/backward-curved, plug fans, EC fans), filtration levels, coil type, and more — making them suitable across building types from offices to industrial facilities.
In short — dual-skin AHUs combine energy efficiency, comfort, air quality, and robustness, making them a significant step up from older/simpler AHUs.
🏭 Where Dual-Skin AHUs Shine (Applications)Because of these advantages, dual-skin AHUs are especially useful in:
Commercial buildings: offices, malls, hotels, multiplexes — where comfort, noise control, and energy efficiency matter.
Healthcare, hospitals, labs, cleanrooms — where air-quality, hygiene, filtration (HEPA), and consistent environmental control is vital.
Industrial, pharmaceutical, food & beverage, electronics manufacturing — where air conditioning, dust control, temperature/humidity stability, and robust construction are needed.
Large-scale HVAC systems: buildings needing high air-volumes (thousands to tens of thousands of CFM), or rooftop/rooftop-mounted AHUs.
₹ 15000 / Piece Get Latest Price
| System Type | Fresh Air Unit |
| Airflow Capacity | 1000 to 6000 |
| Duct Material | SS 304 Duct |
| Hood Material | SS 304 |
| Filter Type | Baffle Filter |
| Fan Type | Axial Fan |
| Control Type | Manual Panel |
| Application | Restaurant, Hotel, Cloud Kitchen, Food Court, Industrial Canteen |
Minimum order quantity: 1 Piece
₹ 10000 / Piece Get Latest Price
| Blower Type | Axial |
| Airflow | 1000 to 60000 |
| Pressure | 50–150 mmWC |
| Phase | Three Phase |
| Motor Power | 0.5 to 30 Hp |
| Application | Dust Collection, Fume Extraction, Cooling, Ventilation, Boiler Air |
| Impeller Material | Mild Steel |
| Drive Type | Direct Drive |
| Mounting Type | Base Mounted |
Minimum order quantity: 1 Piece
₹ 10000 / Piece Get Latest Price
| Cutout Size | 315 mm |
| Air Flow | 1000 m³/hr |
| Voltage | 220 v |
| Size | 18 inch |
| Material | mild steel |
| Brand | coolvent technology |
| Frequency | 50 hz |
| Number Of Blade | 6 |
| Application | VFD Panel, Telecom Cabinet, Inverter Panel, Control Panel, Server Rack |
| Phase | 1 |
| Power | ac/dc |
| Shape | round |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
VentCart High Static Inline Duct Fan — an inline type duct fan that works well for HVAC/ventilation ducts, helpful if your AHU ducts are long or static pressure is moderately high.
Generic AHU Blower Fan — a more generic blower/fan for AHU use — may suit small-to-medium AHUs or retrofits.
Industrial Centrifugal Fan (HVAC / AHU) — a heavy-duty centrifugal fan that could handle higher static pressure or larger air-volume requirements typical in commercial/industrial AHUs.
Divinext 6” Panel Axial Cooling Fan — a small axial fan suited for minor ventilation, exhaust, or small-scale air-circulation tasks. Might work for small AHUs or supplementary ventilation.
Starvin Cabin Ceiling Fan (Basic Cooling Fan) — a simple basic fan; not ideal for full AHU duty but could be used for small-scale air movement or supplementary cooling in small rooms/spaces.
AHUs usually use centrifugal fans (forward- or backward-curved / airfoil / radial) or plug-fans / plenum fans inside the unit. These fans are chosen based on the airflow needed (volume, CFM) and static pressure in the ducts/filters/coils.
Backward-curved centrifugal fans are common in AHUs because they offer good pressure generation, efficiency, relatively low noise, and can handle duct resistance, filters, coils etc.
Alternatively, plug-fans (direct-drive inside AHU housing) or EC-motor fans are increasingly used because they are more compact, energy-efficient, and easier to control (especially if you want variable airflow) than belt-driven fans
Dipender Singh (CEO)
Coolvent Technology
Tekchand Nagar Gali No. - 5, Plot No. - 1717b/31, Khasra No. - 4082/232, Guragon, Tek Chand Nagar
Gurugram - 122016, Haryana, India